Mamie Hoffer and Jason Futrell selected as Small Business Persons of the Year NC-SBA

Mamie Hoffer and Jason Futrell selected as Small Business Persons of the Year NC-SBA

Ahead of National Small Business Week, the U.S. Small Business Administration announced this year’s Small Business Persons of the Year winners from the 50 states…

Product Selector Copy

Back
Are you ready to get started? Explore below using our Product Selector, complete the REQUEST FOR QUOTE, and we’ll contact you shortly with a flow measurement solution and expert answers to your flow measurement questions.
Is your application custom? Tell us a little about yourself and your custom flow needs. A Hoffer product specialist will contact you to help you determine which of our solutions will be best for you, and we’ll provide you a quote.

Product Selector

FLOW METER SELECTION GUIDE-LIQUIDS
PRODUCT
FAMILY/SERIES
SIZES
AVAILABLE
FLOW RANGE NOTABLE SPECS CALIBRATIONS TYPE OF METER CLEAN
LIQUID
DIRTY LIQUID
(SLURRY)
CORROSIVE VISCOUS CRYOGENIC BI-DIRECTIONAL
OPTION
HO LIQUID 1/4″thru12″ 0625 to 15,000 GPM +/-.5% linearity 12-point water Cal NIST traceable.
HFC can provide water Cals upto 1500 GPM.
Higher flow rates are extrapolated.
10″ & 12″ size meters are Calibrated at Utah or Alden.
Inline axial industrial Up to 300 cST
Note 1
API SERIES CUSTODY
TRANSFER
1″ thru 4″ 6 to 1,500GPM +/-.25% linearity
(optional+/-.15%)
12-point water Cal NIST traceable.
HFC can provide water Cals up to 1500 GPM.
Higher flow rates are extrapolated.
10″ & 12″ size meters are Calibrated at Utah or Alden.
Custody transfer of liquid
petroleum products
Up to 300 cST
Note1
CT SERIES CUSTODY
TRANSFER RIM
4″ thru 12″ 120 to 15,000 GPM +/-.15% linearity 12-point water Cal NIST traceable.
HFC can provide water Cals up to 1500 GPM.
Higher flow rates are extrapolated.
10″ & 12″ size meters are Calibrated at Utah or Alden.
High performance Upto300cST Note1
MF SERIES – LIQUID 1/2″ end
connections
.007 to 3.5 GPM +/-1% linearity 12-point water Cal NIST traceable. Low flow 25 cST Maximum
STAR SERIES 1/4 thru 3″ 35 to 650 GPM +/-1% linearity Average K-factor etched on meter housing.
K-factor derived from 3 point water Calibration.
Lower cost than HO
LO-CO SERIES 1/4″ thru 2″ 45 to 225 GPM +/-1% linearity Average K-factor etched on meter housing. Lowest cost available
SANITARY SERIES 1/4″ thru 3″ 25 to 650 GPM +/-.5% linearity* 12-point water Cal NIST traceable. Suitable of pharma, food&beverage
TEFLON SERIES 1/4″ thru 3″ 35 to 485 GPM +/-1% linearity 12-point water Cal NIST traceable. Caustic & aggressive fluids
WECO – LIQUID 1″ thru 4″ 4 to 1, 500 GPM +/-.5% linearity 12-point water Cal NIST traceable. High pressure oil patch
GROOVED – LIQUID 1″ thru 12″ 2 to 12,000 GPM +/-.5% linearity 12-point water Cal NIST traceable.
HFC can provide water Cals up to 1500 GPM.
Higher flow rates are extrapolated.
10″&12″ size meters are Calibrated at Utah or Alden.
Low pressure oil patch
HOG SERIES 1″end
connections
.4 – 25 GPM +/-.25% linearity 12-point Cal at approx. 100 cstks. High viscosity liquids>100 CSTK
HP SERIES – LIQUID 4″ line size & larger .25 tp 50 FPS +/-1% linearity 12-point water Cal NIST traceable in FPS. insertion flow meter Consult Factory
HHP (HIGHPRESSURE)
-LIQUID
1/4″ thru 2″ .0625 to 275 GPM +/-.5% linearity* 12-point water Cal NIST traceable. High pressure flanged Up to 300cST
Note1
HOSEBARB – LIQUID 1/4″ thru 3″ .0625 to 800 GPM +/-.5% linearity* 12-point water Cal NIST traceable. Typically used as “quick connect” Up to 300 cST
Note1
AUTOCLAVE – LIQUID 1/4″ thru 3/4″ .0625 to 35 GPM +/-.5% linearity* 12-point water Cal NIST traceable. High pressure threaded connections.
Up to 20,000 PSI
Up to 300 cST
Note1
SHORT WAFER – LIQUID 5/8 thru 8″ .2 to 6, 400 GPM +/-.5% linearity 12-point water Cal NIST traceable. Cost savings flanged meter solution
Up to 20,000PSI
Up to 300 cST
Note1
TRI – FLO – LIQUID 1″ thru 2″ 4 to 260 GPM +/-1% linearity 12-point water Cal NIST traceable. Insertion, low cost, flowmeter
STEAMJACKETED-LIQUID 1/4″ thru3 “ .25 to 800 GPM +/-.5% linearity* 12-point water Cal NIST traceable. Used on liquid applications where liquids may solidify
Note1:In-house viscosity calibrations are limited to 100cST up to 60 GPM. Thirdparty viscosity calibrations are required for flowrated > than 60 GPM and viscosities from 100 to 300 cST.
LEGEND SUITABLE=
NOT SUITABLE=
APPLICATION DEPENDENT=
MAYBE SUITABLE DEPENDING ON METER CONSTRUCTION=
*+/-1.0%linearityon1/4″meter

GENERAL INDUSTRIAL

Turbine Flow Meters:

Upstream Oil and Gas:

  • High Pressure (15,000 PSI) for water, liquid carbon dioxide, cement and slurry Oil Patch and Industrial for Water, Water/Sand and Liquid Carbon Dioxide
  • “Patented” liquid flow meter. The unique system provides cost and space savings in the Oil Patch.
  • Custom subsea flow metering solutions.

Custody Transfer-Refined Products:

Insertion Style:

Sanitary Applications:

Low-Flow Applications:

High-Pressure Applications:

  • Pressure ratings of 3000, 6000, 8000 and 10,000 psi
  • Pressure ratings of 10,000/ 15,000 and 20,000 with autoclave end fitting

Corrosive Service:

High Viscosity Applications

Military Application:

Cryogenics:

Rate Indicator/Totalizers:

  • Indicator/Dual Totalizers w/ Modbus & Data Logging for Liquids
  • Temperature and Pressure Flow Computer for Liquids
  • Indicator/Totalizer with HART Communications Protocol

Conditioners, Amplifiers, Transmitters:

  • Microprocessor Controlled Transmitter w/ Linearization / DC power / 4-20 mA Analog Output
  • Transmitter / DC/AC power / Scaled Pulse/4-20 mA Analog output
  • Microprocessor Controlled Transmitter w/Linearization / Scaled Pulse / 4-20mA Analog Output / DC/AC power
  • Digital to Analog Converter Mag Type for use with Lo-Co
  • Preamp Signal Conditioner Mag Type for use with Lo-Co

Printers:

  • Compact Printer for use with Nova-Flow and Flowstar
  • ICE and ACE Cryogenic Electronic Printer
  • ICE and ACE Cryogenic Portable Printer

General Industrial :

Oil/Gas:

Insertion Style / Large Pipe Diameters:

Low Flow Applications:

Rate Indicator/Totalizers:

  • Digital Gas Flow Computer with Modbus & Data Logging
  • with HART Communications Protocol

Conditioners, Amplifiers, Transmitters:

  • Microprocessor Controlled Transmitter w/ Linearization / DC power / 4-20 mA Analog Output
  • Transmitter / DC/AC power / Scaled Pulse/4-20 mA Analog output
  • Microprocessor Controlled Transmitter w/Linearization / Scaled Pulse / 4-20mA Analog Output / DC/AC power

Printers:

  • Compact Printer for use with Nova-Flow and Flowstar

LIQUID TURBINE FLOWMETER APPLICATIONS
AND GAS TURBINE FLOWMETER APPLICATIONS[]

  • Liquid Applications

    We provide best solutions that will meet the extreme conditions
    associated with your subsea and oil and gas applications.

    We provide best solutions that will meet the extreme conditions associated with your subsea and oil and gas applications.

    LEARN MORE []
  • Gas Applications

    We offer complete flow measurement packages for the offshore drilling, production and well-servicing environments.

    We offer complete flow measurement packages for the offshore drilling, production and well-servicing environments.

    LEARN MORE []

VISIT OUR BLOG: FLOW INSIDER

Read Hoffer Flow Controls products, news, and announcements regarding private markets, Federal agencies, the US military using Hoffer Flow Control flowmeters, and much more. READ MORE

FEATURED VIDEO

RESOURCES

The Hoffer Collection

View our complete collection of product offerings and other valuable information.

Location []